New NAL-NL3 Research Offers Hearing Aid Fitting Guidance for Adults with Minimal Hearing Loss

Image
HHTM
November 15, 2026

For many audiologists, it is a familiar clinical scenario: a patient reports difficulty following conversations in restaurants, group settings, or other noisy environments, yet their hearing test shows normal or near-normal results. While these communication difficulties may be significant, conventional hearing aid fitting approaches have offered limited guidance on whether amplification could help or how much gain should be prescribed.

Newly published research from Australia’s National Acoustic Laboratories (NAL) examines one approach to addressing this challenge through the NAL-NL3 Minimal Hearing Loss (MHL) Module. Published November 14, 2026, in the International Journal of Audiology, the study evaluates a fitting strategy designed for adults who experience hearing difficulties despite having little or no measurable hearing loss on a conventional audiogram.

The findings add to the growing body of research supporting NAL-NL3, which is already entering clinical practice through hearing aid manufacturers’ fitting software. While the broader fitting system is becoming increasingly familiar to hearing care professionals, the newly published study provides additional evidence supporting its application to a group of patients whose everyday listening difficulties are not fully reflected in their audiometric thresholds.

Addressing Hearing Difficulties Beyond the Audiogram

Pure-tone audiometry remains an essential part of hearing assessment, but it does not capture every aspect of a person’s ability to communicate in everyday situations.

Some adults with normal or near-normal hearing thresholds experience considerable difficulty understanding speech when background noise, competing conversations, or other challenging listening conditions are present. These difficulties can contribute to listening fatigue, reduced communication confidence, and frustration, even when hearing sensitivity appears relatively good.

For clinicians, this creates a treatment dilemma. Communication strategies, counseling, and environmental modifications can help, but conventional hearing aid prescriptions generally provide little or no amplification when hearing thresholds are within normal limits.

Consequently, even when modern hearing aids offer directional microphones, beamforming, and advanced noise reduction features, patients with minimal hearing loss may not receive enough amplification to take full advantage of those technologies.

The MHL Module was developed to address this gap, providing evidence-informed fitting targets intended to improve listening in challenging environments without introducing unnecessary loudness or discomfort.

How the Minimal Hearing Loss Module Works

NAL-NL3 builds on the widely used NAL-NL2 prescription while introducing a more flexible approach to different listening needs. Alongside its standard prescription, the system includes specialized modules addressing listening comfort in noise and hearing difficulties among individuals with minimal hearing loss.

The development of NAL-NL3, including its approach to patients with minimal or no measurable hearing loss, was explored in a This Week in Hearing discussion with NAL researcher Pádraig Kitterick. The conversation examined how the updated fitting system incorporates clinical experience and research to address listening challenges that traditional prescriptions may not adequately accommodate.

Unlike conventional prescriptions that primarily compensate for reduced hearing sensitivity, the MHL Module provides modest amounts of amplification intended to help users benefit from hearing aid features that improve the signal-to-noise ratio.

The fitting targets generally emphasize frequencies important for speech understanding while minimizing unnecessary low-frequency amplification. The goal is not simply to make sounds louder, but to provide enough amplification for hearing aid processing to improve listening in challenging environments while preserving comfort and sound quality.

Importantly, the module is designed primarily for situational use in difficult listening environments, rather than necessarily recommending continuous hearing aid use throughout the day.

Study Evaluates Speech Clarity and Listening Effort

To develop and evaluate the MHL Module, researchers conducted a series of prospective studies involving 71 adults with normal or near-normal audiometric thresholds who reported hearing difficulties and did not already own hearing aids.

The research combined laboratory speech perception testing with real-world hearing aid evaluations. Participants provided feedback on their listening experiences in everyday environments through repeated surveys, allowing researchers to examine perceived benefit, comfort, and satisfaction across different hearing aid brands and fitting approaches.

The module was refined through multiple stages of testing, with adjustments made in response to participants’ experiences and preferences.

According to the researchers, field trials demonstrated several encouraging outcomes. Participants reported improved speech clarity and reduced listening effort with the MHL fitting targets, particularly in noisy listening situations.

Participants also preferred the MHL approach when listening in noise compared with a conventional prescription that provided little or no additional gain. Successive refinements to the fitting strategy were associated with improvements in user satisfaction and perceived benefit.

The researchers concluded that the final version of the module met its intended goal of providing amplification that was beneficial, acceptable, and safe for adults with minimal hearing loss.

What the Findings Mean for Clinical Practice

For audiologists, the research offers additional evidence supporting a potential treatment option for patients whose reported communication difficulties appear disproportionate to their audiometric results.

Rather than relying exclusively on hearing thresholds to determine whether hearing technology might be beneficial, the MHL Module provides a structured approach to considering amplification for specific functional listening needs.

However, the findings should not be interpreted as suggesting that everyone with a normal audiogram and difficulty hearing in noise requires hearing aids.

Careful assessment remains essential, including consideration of patient-reported difficulties, speech-in-noise performance, listening environments, and other factors that may contribute to communication challenges. The patient’s goals and motivation to try hearing technology are also important considerations.

Device selection and fitting remain important. Because the module is intended to help users take advantage of directional processing and other noise-management features, appropriate acoustic coupling and verification of prescribed gain are particularly relevant. Clinicians must also consider listening comfort, sound quality, and realistic expectations regarding benefit.

The study has limitations. Although the research included laboratory and real-world evaluations, the total sample was relatively modest, and the findings do not establish long-term outcomes or demonstrate that the approach will benefit every individual with minimal hearing loss.

Expanding Options for Individualized Hearing Care

The newly published findings add further clinical evidence to the evolving NAL-NL3 fitting system, particularly its application to adults with minimal hearing loss who experience persistent communication difficulties.

As NAL-NL3 becomes more widely incorporated into hearing aid fitting software, the research may help clinicians better understand when and how its specialized modules can be used to address individual listening needs.

While additional research will help clarify which patients benefit most and how those benefits are maintained over time, the findings reinforce an important principle in hearing healthcare: hearing thresholds alone do not always tell the complete story of a person’s listening difficulties.

Reference: Kitterick, P. T., et al. (2026). Fitting hearing aids beyond the audiogram: The NAL-NL3 Minimal Hearing Loss Module. International Journal of Audiology. https://doi.org/10.1080/14992027.2026.2758956

Email Marketing by Benchmark